training-image
Back to education

IEC 61850 University Training Tier I and Tier II

We offer a 5 day training course. Four out of five days include practical exercises, during which engineers configure IEC 61850 servers, clients & learn how to use modern testing tools.

IEC 61850 University Training Tier I and Tier II

Tutors of the course: conveyor of working group (WG) 10 of the IEC TC 57 - Christoph Brunner (it4power), and WG 10 members - Dustin Tessier (Tesco Automation). Alexander Golovin and Alexey Anoshin (both - TEKVEL).

We invite to participate: protection, automation and control engineers of electric power utilities, design and commissioning specialists, developers.

Read all

Program

Presented content of the training is preliminary. Final training content may be modified.

Aug. 6, 2018

Day 1 — IEC 61850 Fundamentals

Duration

Contents

9:30 a.m. - 10 a.m.

Registration

Welcome coffee and registration of participants

10 a.m. - 10:50 a.m.

Introduction to IEC 61850

  • Communications in electric power utilities.
  • Existing communication protocols, prerequisites for IEC 61850 development. 
  • IEC 61850 overview - what is defined by the standard and what is not?

10:50 a.m. - 1:10 p.m.

Information model

  • Basic elements of information model: logical device, logical node, data objects and data attributes.
  • Common data classes.
  • Principles of data modeling.
  • Examples (modeling of protection, automation, measurement functions and etc.).

1:10 p.m. - 2:10 p.m.

Lunch

2:10 p.m. - 3:10 p.m.

SCL (System Configuration Language)

  • SCL basics. SCL-schema.
  • Using SCL to describe information model of IEDs.
  • SCL file types.
  • Validation of files.

3:10 p.m. - 3:25 p.m.

Coffee break

3:25 p.m. - 4:10 p.m.

Communication services and protocols

  • Why to use abstract models?
  • Abstract models and services.
  • Mapping on the specific communicaion protocols.

4:10 p.m. - 5:30 p.m.

Local Area Network (LAN) basics

  • LAN infrastructure.
  • Role and meaning of parameters: MAC-address, IP-address, subnet mask and etc.
  • Data exchange at link layer.

5:30 p.m. - 6:10 p.m.

IEC 61850 standard package overview

  • Different types of IEC documents.
  • Overview of published documents and documents under development.

Aug. 7, 2018

Day 2 — Sampled Values

Duration

Contents

10 a.m. - 10:30 a.m.

Process bus

  • Main components, terminology.
  • Process bus configuration.
  • Communications in process bus.

10:30 a.m. - noon

Transmission of Sampled Values

  • Abstract model. Sampled Values Control Block definition, communication services.
  • Mapping on the specific communication protocol (IEC 61850-9-2).
  • Implementation Guideline For Digital Interface To Instrument Transformers Using IEC 61850-9-2.
  • IEC 61869-9 – Digital Interface For Instrument Transformers.
  • SCL configuration files.
  • Traffic load estimation.

noon - 12:15 p.m.

Coffee break

12:15 p.m. - 1 p.m.

Time Synchronization

  • 1PPS time synchronization.
  • IEEE C37.238/IEC 61850-9-3.

1 p.m. - 2 p.m.

Lunch

2 p.m. - 2:30 p.m.

Overview of the IEC 61850-9-2 compliant equipment

  • Overview of the primary equipment.
  • Overview of the secondary equipment.

2:30 p.m. - 3 p.m.

Overview of IEC 61850-9-2 process bus projects

Overview of IEC 61850-9-2 process bus projects and their protection, control and measurement applications.

3 p.m. - 3:15 p.m.

Coffee break

3:15 p.m. - 6 p.m.

IEC 61850-9-2 hands-on session

  • Configuration of a stand-alone merging unit (publishing of 80/256 samples/cycle). Analysis of the traffic, using contemporary software tools.
  • Configuration of IEC 61850-9-2LE protection IED. Perfomance testing.
  • Configuration of merging unit software simulator (publishing of 80 samples/cycle), management of quality attributes, time synchronization status and etc. Analysis of the traffic, using contemporary software tools.

Aug. 8, 2018

Day 3 — Reporting, logging, controls and settings group definition/control

Duration

Contents

10 a.m. - 11:30 a.m.

Reporting

  • Application areas, general considerations.
  • Buffered and unbuffered reporting.
  • Abstract model. Report control block structure,communication services.
  • SCL configuration.
  • Mapping on the specific communication protocol (IEC 61850-8-1).
  • Application recommendations.

11:30 a.m. - 11:45 a.m.

Logs

  • Application areas, general considerations.
  • Abstract model. Log model, Log Control Block structure, communication services.
  • Mapping on the specific communication protocol (IEC 61850-8-1).
  • Application recommendations.

11:45 a.m. - noon

Coffee break

noon - 12:40 p.m.

Controls

  • Application areas, general considerations.
  • Abstract model. Direct control, select before operate (with normal/enhanced security), communication services.
  • Mapping on the specific communication protocol (IEC 61850-8-1).
  • Application recommendations.

12:40 p.m. - 1 p.m.

Settings Group Definition and Control

  • Application areas, general recommendations
  • Abstract model. Setting Group Control Block structure, communication services.
  • Mapping on the specific communication protocol (IEC 61850-8-1).
  • Application recommendations.

1 p.m. - 2 p.m.

Lunch

2 p.m. - 6 p.m.

IEC 61850-8-1 (MMS) hands-on session

  • Configuration of unbuffered reporting (transmission of measurements).
  • Configuration of buffered reporting (transmission of indications).
  • Configuration of control models.
  • Configuration of logs.

Aug. 9, 2018

Day 4 — Generic Object Oriented Substation Event

Duration

Contents

10 a.m. - 11:30 a.m.

Generic Object Oriented Substation Event (GOOSE)

  • Application areas, general considerations.
  • Abstract model. GOOSE Сontrol Block structure, communication services.
  • SCL configuration.
  • Mapping on the specific communication protocol (IEC 61850-8-1).
  • Application recommendations.

11:30 a.m. - 11:45 a.m.

Coffee break

11:45 a.m. - 3:45 p.m.

GOOSE hands-on sessions, part 1

  • Implementation of reverse blocking scheme.
  • Implementation of arc-flash protection.
  • Performance testing of the protection IED (GOOSE vs. hardwired output) using IEC 61850-compliant test set.

3:45 p.m. - 4:45 p.m.

Lunch

4:45 p.m. - 6 p.m.

GOOSE hands-on sessions, part 2

  • Implementation of reverse blocking scheme.
  • Implementation of arc-flash protection.
  • Performance testing of the protection IED (GOOSE vs. hardwired output) using IEC 61850-compliant test set.

Aug. 10, 2018

Day 5 — IEC 61850 system engineering process

Duration

Contents

10 a.m. - noon

System Engineering Process Overview

  • Existing approaches to design IEC 61850 based systems.
  • Development of SSD (System Specification Description) files.
  • Overview of ICD (IED Capabilities Description) files.
  • Development of SCD (System Configuration Description) files.
  • Overview of IEC 61850 System Configuration Tools.
  • Overview of tools for verification and acceptance of SCD files.

noon - 12:15 p.m.

Coffee break

12:15 p.m. - 1 p.m.

New features of IEC 61850 Edition 2 and Edition 2.1

  • Model extensions.
  • Supervision of GOOSE and Sampled Values communications.
  • Testing features, introdcued by IEC 61850.

1 p.m. - 2 p.m.

Lunch

2 p.m. - 4 p.m.

Project implemenatation demo using IEC 61850 System Configuration Tool

  • SSD (System Specification Description) development demo.
  • SCD (System Configuration Description) development demo.
  • Using developed SCD file to configure IEDs.

4 p.m. - 4:15 p.m.

Coffee break

4:15 p.m. - 5:15 p.m.

SCD files validation, visualization and application verification demo

  • Validation of SCD files.
  • GOOSE and Sampled Values communications validation.
  • GOOSE and Sampled Values communications application checks.
  • Generation of project documentation on the basis of SCD file.

5:15 p.m. - 6 p.m.

Generation of documentation on signals, transmitted to process control system or RTU on the basis of SCD file

  • Interpretation of IEC 61850 logical nodes and data objects.
  • Generation of documentation on signals, transmitted to process control system or RTU, via buffered or unbuffered reporting on the basis of SCD file.

Service cost

 

Participation packages

Base price — is a price for one participant representing one company attending a training, organized by TEKVEL Ltd. for the first time.

Two or more — price per participant, when 2 or more participants are delegated for the same training by the same company

Returning customer — price for the companies, which have already delegated their staff to our trainings; does not depend on the number of participants delegated.

Package Package description Package and description Price per participant, USD
Basic

Day 1, Day 2 and Day 3

Basic

Day 1, Day 2 and Day 3

Base

1440

Two or more

1152

Returning customer

1008

Communication services

Day 2, Day 3 and Day 4

Communication services

Day 2, Day 3 and Day 4

Base

1760

Two or more

1408

Returning customer

1232

IEC 61850 data model and communication services

Day 1, Day 2, Day 3 and Day 4

IEC 61850 data model and communication services

Day 1, Day 2, Day 3 and Day 4

Base

1950

Two or more

1560

Returning customer

1365

Full course

All days

Full course

All days

Base

2380

Two or more

1904

Returning customer

1666

Package

Basic

Day 1, Day 2 and Day 3

Price per participant, USD

Base

1440

Two or more

1152

Returning customer

1008

Package

Communication services

Day 2, Day 3 and Day 4

Price per participant, USD

Base

1760

Two or more

1408

Returning customer

1232

Package

IEC 61850 data model and communication services

Day 1, Day 2, Day 3 and Day 4

Price per participant, USD

Base

1950

Two or more

1560

Returning customer

1365

Package

Full course

All days

Price per participant, USD

Base

2380

Two or more

1904

Returning customer

1666

The cost of participation in the seminar by day

Base price — is a price for one participant representing one company attending a training, organized by TEKVEL Ltd. for the first time.

Two or more — price per participant, when 2 or more participants are delegated for the same training by the same company

Returning customer — price for the companies, which have already delegated their staff to our trainings; does not depend on the number of participants delegated.

Day Content Price per participant, USD
1 IEC 61850 Fundamentals

Base

400

Two or more

320

Returning customer

280

2 Sampled Values

Base

600

Two or more

480

Returning customer

420

3 Reporting, logging, controls and settings group definition/control

Base

800

Two or more

640

Returning customer

560

4 Generic Object Oriented Substation Event

Base

800

Two or more

640

Returning customer

560

5 IEC 61850 system engineering process

Base

800

Two or more

640

Returning customer

560

Day 1

IEC 61850 Fundamentals

Price per participant, USD

Base

400

Two or more

320

Returning customer

280

Day 2

Sampled Values

Price per participant, USD

Base

600

Two or more

480

Returning customer

420

Day 3

Reporting, logging, controls and settings group definition/control

Price per participant, USD

Base

800

Two or more

640

Returning customer

560

Day 4

Generic Object Oriented Substation Event

Price per participant, USD

Base

800

Two or more

640

Returning customer

560

Day 5

IEC 61850 system engineering process

Price per participant, USD

Base

800

Two or more

640

Returning customer

560